Sale!

Bently Nevada 176449-05 | 3500/64 Dynamic Pressure Monitor, UL Listed, Factory Sealed

Original price was: $3,488.00.Current price is: $3,288.00.

Parameter Value
Platform Compatibility Bently Nevada 3500 Machinery Protection Rack
Number of Input Channels 4 dynamic pressure input channels
Nominal Power 24 VDC, powered from 3500 rack backplane
Typical Power Draw 8 W
Transducer Supply -24 VDC for 3-wire sensors; 3.3 mA current source for 2-wire sensors
Frequency Filter Ranges Low: 5 Hz–4 kHz; High:10 Hz–14.75 kHz
Per-Channel Outputs Buffered coaxial output, 4–20 mA recorder output
Category: SKU: 176449-05 Tag: Brand:

Description

Unboxing & Physical Snapshot

  • Brand & Model: Bently Nevada 176449-05, 3500/64 Dynamic Pressure Monitor
  • Physical Dimensions: 9.50 in H × 0.96 in W × 9.52 in D
  • Estimated Shipping Weight: 1.8 lb (packaged with ESD foam and rigid corrugated carton)
  • What’s in the Box: Dynamic pressure monitor module, front-panel BNC connectors, gold-plated edge connector, factory serial test certificate; dynamic pressure transducers and coaxial cables sold separately.

 

Product Introduction (Structure A: Environmental hook)

This monitor captures high-frequency dynamic pressure waveforms inside gas turbine combustors, where extreme thermal cycling and broadband engine noise distort low-level transducer signals. It processes fast pressure fluctuations from high-temperature dynamic pressure transducers, supplying waveform and bandpass amplitude data for combustion instability detection and machinery protection logic.

Each channel includes hardware bandpass filtering to isolate combustion events from low-frequency process pressure drift. (Unfiltered raw pressure signals often trigger false alarms during normal load swings.) The conformal-coated PCB guards sensitive high-impedance front-end circuits from particulate contamination in non-conditioned control rooms.

 

Core Technical Specifications

 

Parameter Value
Platform Compatibility Bently Nevada 3500 Machinery Protection Rack
Number of Input Channels 4 dynamic pressure input channels
Nominal Power 24 VDC, powered from 3500 rack backplane
Typical Power Draw 8 W
Transducer Supply -24 VDC for 3-wire sensors; 3.3 mA current source for 2-wire sensors
Frequency Filter Ranges Low: 5 Hz–4 kHz; High:10 Hz–14.75 kHz
Per-Channel Outputs Buffered coaxial output, 4–20 mA recorder output
Operating Ambient Temp -30 °C to +65 °C
Storage Temperature -40 °C to +85 °C
Relative Humidity (operating) 5% to 95%, non-condensing
Construction FR4 PCB, conformal coating, gold-plated edge connector

 

Global Compliance & Industry Certifications

  • CE Mark
  • UL/cUL Listed
  • SIL 2 capable (system-level evaluation required)
  • ATEX / IECEx available for qualified production lots
  • API 670 compliant for combustion pressure monitoring applications

The UL/cUL listing establishes PCB creepage and material flammability requirements, limiting internal arc propagation if front-end transducer supply components fail. Verify specific lot certifications with OEM.

 

Long-Term Storage & Asset Preservation Guide

Keep the module sealed inside its original ESD shielding bag and shipping carton while held as shelf spare. Even mild electrostatic discharge can degrade the high-impedance transducer input circuitry and introduce noisy pressure waveforms after rack installation.

Inspect electrolytic capacitors every 24 months for assets stored longer than three years. Controlled voltage reforming is required for spares held past four years; aged capacitance distorts high-frequency waveform capture during turbine startup.

Do not stack heavy rack modules on the module faceplate. Compressive load can bend edge connector pins and crack conformal coating, allowing dust to settle on high-speed analog traces.

 

Physical Installation Prerequisites

Leave a minimum of 40 mm vertical clearance above and below the populated 3500 rack for convection cooling. Elevated junction temperatures shift filter response and distort combustion pressure peak readings.

Slide the module fully into the rack slot until the front latch engages and locks the edge connector to the backplane. Connect the 3500 rack chassis to plant instrument earth; floating chassis potentials inject common-mode noise onto the BNC transducer signal lines.

 

Buyer’s FAQ

Q: What HS tariff code applies to Bently Nevada 176449-05 for cross-border shipments? A: Primary HS classification falls under 853710 for electronic monitoring assemblies for rotating machinery protection. Confirm classification with your customs broker before export filings, as rulings depend on supporting technical documentation.

Q: What country of origin is marked on Bently Nevada 176449-05? A: Country of Origin is United States. This marking appears on the module nameplate and must be reproduced on commercial invoices for cross-border compliance audits.

Q: Does 176449-05 ship preloaded with firmware? A: Yes. Base firmware is factory loaded. Channel filter ranges, alarm thresholds and transducer scaling must be configured via 3500 configuration software after rack integration.

Q: Should I purchase all-risk shipping insurance for this spare dynamic pressure monitor? A: Yes. Edge pin damage or hidden PCB microcracks from transit shock may only surface once powered and connected to combustion pressure transducers. All-risk insurance covers full replacement value for handling defects.

Bently Nevada 330180-51-CN 3300 XL 5m Proximitor Sensor, DIN Rail Mount
Bently Nevada 330930-065-01-00 6.5m 3300 XL NSv Probe Extension Cable
Bently Nevada 330130-080-01-CN 8m 3300 XL 8mm Armored Probe Extension Cable
Bently Nevada 330104-00-11-10-02-05 3300 XL 8mm Proximity Probe