Description
Product Overview
Part Number: 330103-00-05-10-02-00 Manufacturer: Bently Nevada (Baker Hughes) Product Series: 3300 XL 8 mm Proximity Probe Type: Non-contact eddy current proximity probe, non-armored triaxial integral cable, M10×1 metric thread, USA manufactured. This 8mm short case eddy current proximity probe is designed for limited space mounting locations. It measures shaft radial vibration, thrust displacement, shaft position and keyphasor speed signals on rotating machinery including steam turbines, centrifugal compressors, generators and large process pumps. Paired with matched 3300XL proximitor and Bently 3500 monitoring rack, it delivers real-time displacement signals for machinery protection and predictive condition monitoring, fully compliant with API 670 standard. The suffix -00 represents standard version without extra factory calibration certificate.
Technical Specifications
| Item | Parameter |
|---|---|
| Probe Size | 8 mm |
| Linear Measurement Range | 0 ~ 8 mm |
| Scale Factor | 7.87 V/mm (200 mV/mil) |
| Integral Cable Length | 10m |
| Thread Specification | M10×1 metric thread |
| Probe Tip Material | PPS polyphenylene sulfide |
| Operating Temperature | -45°C ~ +100°C |
| Storage Temperature | -55°C ~ +125°C |
| Lateral Sensitivity | ≤7% |
| Linearity Error | ≤1% of full scale |
| Connector | ClickLoc miniature coaxial connector |
| System Compatibility | 3300XL proximitor, 3500 series machinery monitoring rack |
| EMC Performance | RFI/EMI interference resistant |
| Cable Type | Non-armored triaxial cable |
| Case Length | 0.5 inch |
| Suffix 00 | Standard base version |
Engineer Notes
- This 330103 non-armored probe must be matched with corresponding 3300XL 8mm proximitor. The total system cable length must strictly comply with datasheet requirement to guarantee scale factor precision.
- Recommended working gap for standard 8mm 3300XL probe: approximately 1.25 mm. Verify gap voltage during site commissioning.
- Target surface must be ferrous conductive steel. Non-ferrous materials will shift scale factor and reduce measurement accuracy.
- Protect PPS probe tip from mechanical impact and scratches; tip damage will result in unstable signal and measurement drift.
- Do not splice, cut or modify factory integral triaxial cable. Unauthorized cable modification voids calibration and product warranty.
- Apply proper torque on M10 threads during installation; over-tightening may crack probe housing and damage internal components.
- Ultra-short 0.5-inch probe body for tight mounting cavities; non-armored cable suitable for low-abrasion cable routing environments.
- The -00 suffix is standard version without factory calibration certificate. If calibration document required, select -05 variant.
Pre-Shipment Test Protocol
- Continuity & insulation resistance test of probe and attached integral cable
- Scale factor and linearity test with standard steel target and precision gap gauge
- Noise floor and output signal stability check
- Full visual inspection: cable jacket, ClickLoc connector, probe tip and thread condition
- Part number, label and marking verification
- Anti-static & shockproof packaging inspection
Buyer FAQ
Q: Is 330103-00-05-10-02-00 new original? A: We supply brand new original Bently Nevada units, 12-month warranty, factory test certificate available on request.
Q: What monitoring system works with this probe? A: It pairs with Bently Nevada 3500 machinery protection rack and matching 3300XL 8mm proximitor.
Q: What is the difference between 330103 and 330104 series probes? A: 330103 series uses non-armored cable; 330104 is armored cable. Electrical specifications are identical, only cable armor differs.
Q: What is the difference between suffix 00 and 05? A: Electrical performance remains the same. -00 is standard version, -05 comes with factory calibration test certificate.