Woodward WIP11I1E1 | Self-Powered Overcurrent Protection Relay

Original price was: $4,588.00.Current price is: $4,388.00.

Parameter Value
CT Input Rating 1 A
Protection Functions Time overcurrent, instantaneous overcurrent, earth fault protection (ANSI 50,51)
Communication RS485, Open Data Protocol
Power Source Self-powered via CT, no auxiliary voltage
Mounting Panel mount
Weight 1.8 kg
Dimensions 260 × 140 × 120 mm
Country of Origin Germany
Category: SKU: WIP11I1E1 Tag: Brand:

Description

Manufacturer: Woodward SEG Part Number: WIP11I1E1 Internal No.: 503028-001 Product Type: CT-powered Time Overcurrent & Earth Current Relay (WIP1 series)

 

Product Overview

The WIP11I1E1 is a transformer-fed protective relay designed for overcurrent and earth fault protection. It draws operating energy directly from 1A current transformers, no auxiliary supply required. Widely deployed on generators, medium-voltage switchgear and distribution networks for ANSI 50/51 protection functions.

 

Technical Specifications

Parameter Value
CT Input Rating 1 A
Protection Functions Time overcurrent, instantaneous overcurrent, earth fault protection (ANSI 50,51)
Communication RS485, Open Data Protocol
Power Source Self-powered via CT, no auxiliary voltage
Mounting Panel mount
Weight 1.8 kg
Dimensions 260 × 140 × 120 mm
Country of Origin Germany

 

Key Features

  1. Self-powered design, operates purely from CT secondary current; works even when station auxiliary power fails.
  2. Combined phase overcurrent and residual earth fault protection in single unit.
  3. Fully configurable trip curves, adjustable pickup and time delay settings.
  4. RS485 serial port for remote parameterisation, fault recording and status interrogation.
  5. Robust hardware for industrial power plant & substation environments.
  6. Suitable for generator, motor and feeder protection applications.

 

Application Scenarios

  • Generator protection in power stations
  • Medium voltage distribution feeders
  • Motor protection for large industrial drives
  • Islanded power networks where auxiliary supply reliability is critical

 

Installation & Maintenance Notes

  • Connect only to 1A current transformers as specified.
  • Verify CT polarity before commissioning; incorrect wiring leads to protection malfunction.
  • Download fault event logs via RS485 for post-trip root cause analysis.
  • Inspect wiring terminals periodically for corrosion or loose connections.
  • Test protection characteristic curves during scheduled outage maintenance.

 

FAQ

Q: Does WIP11I1E1 need 24V/110V auxiliary power supply? A: No. It is CT self-powered, the relay gets energy from the connected 1A current transformers.

Q: What ANSI codes does this relay support? A: ANSI 50 (instantaneous overcurrent) and ANSI 51 (time overcurrent), plus earth fault protection.

Woodward 5501-471 | NetCon SIO Serial Communication Module for MicroNet Plus
Woodward 5466-253 | MicroNet TMR High Density Combo Analog I/O Module
Woodward 5453-277 | MicroNet TMR Chassis, UL Listed, Factory Sealed Condition
Woodward 5501-381 | MicroNet TMR 220VAC Main Power Supply Module